ZEM8/E Installation Guide

Dimensions and weight

Please see diagram for dimensions and weight of product.

RS485 bus wiring

Connect the expander to the control panel as shown in the wiring diagram.

LEDs

The green power LED will illuminate when power is applied to the expander.

Addressing the expander

Using a two pin jumper, address the expander as the next available expander on the RS485 bus. Once the jumpers are on the correct headers, press and hold the reset button for 5 seconds. Please see the table for help addressing the expander.

 

Jumper
Headers
 Expander Address
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
1
2
4
8
16
32

indicates that a jumper should be placed on this header

leave this header without a jumper on

Please note: Once the expander has been wired to the control panel and addressed, the expander will need to be programmed in to the system on the control panel. Please refer to the control panel guide.

Input wiring

The inputs must be wired DEOL or 3EOL between a 'COM' and a zone terminal. Please see diagram for an example of 3EOL wiring.

Please note: The resistors used are decided by the option selected in menu 'CHOOSE MODE' or 'WIRING CHOICE' in the control panel. Please see control panel guide for more details.

Inertia inputs

If any of the expander inputs are being used as inertia inputs, then the expander must be used in the 1k/1k resistance wiring range.

Fuse protection

Each 12VDC auxiliary output is protected by a 350mA PPTC fuse which should not be exceeded.

 

The fuse will trip when either the load surpasses the fuses maximum capacity or there is a short circuit. These fuses will reset when the issue that is causing the fuse to trip is reversed.

Expander tamper

An external tamper can be wired to the expander. This double pole circuit is wired between the 'COM' and 'T' terminals.

To disable the tamper, a two pin jumper is placed on the 'hold off' header.

Specifications

Input voltage
Tamper switches
Humidity

~9-16VDC

Closed loop circuit wired to terminals

~85% @ 25°c

Current consumption
Temperature
Dimensions and weight (W x H x D)

Quiescent: ~40mA @12VDC

Storage: -40°C to +80°C

100 x 40 x 14mm

 

Operating: -10°C to +40°C

33.5g

Certifications

Security grade (SG) 2

Environmental class (EC) II

EN 50131-1: 2006 + A1: 2009 + A2: 2017 Alarm systems – Intrusion and hold-up systems – Part 1: System requirements

EN 50131-3: 2009 Alarm systems – Control and Indicating Equipment (CIE)

EN 50130-4: 2011 +A1:2014 Immunity requirements for components of fire, intruder and social alarm systems.

EN 50130-5:2011 Alarm systems. Environmental test methods

Warranty and compliance

This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of two years. For further warranty information visit:https://www.pyronix.com/terms-conditions-sales/

The declaration of conformity and further compliance documentation may be downloaded by clicking here

Product information

For electrical products sold within the European Community. At the end of the electrical products life, it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country. This product is approved for use in the Residential, Commercial and Light Industrial Environments.