PCX-RIX8i
Description
Key Features
- 8 inertia inputs
- Complies with EN50131
The PCX-RIX8i lets you expand the security system with a further 8 wired inertia inputs (all of which can be used for roller shutters). This gives you the ability to seamlessly adapt your installation as required.
The lightweight and strong polycarbonate plastic housing of the RIX8i comes with both front and rear tamper protection for extra peace of mind that you are fully protected and conforming to EN50131 regulations.
The PCX-RIX8i can utilise DEOL, SEOL, NC, inertia inputs, or 8 roller shutter inputs.
EN 50131–1:2006+A1:2009 | EN 50131–3:2009 | EN50131–6:2008 | PD6662:2010
Plastic housing |
Yes |
Tamper protection |
Front and rear |
Input type |
DEOL, SEOL, NC, Inertia |
Roller shutter inputs |
8 |
Storage temperature |
-20C to +60C |
Certified operating temperature |
-10C to 40C |
Nominal operating temperature |
-10C to +50C |
Physical dimensions (H x W x D) |
173 x 125 x 32mm | PCB; 128 x 87 x 16mm |
Operating voltage |
9-15V |
Quiescent current consumption |
45mA |
Security Grade |
Grade 2 |
Environmental class |
II |
EN Certificate |
EN50131-3:2009 | EN50131-1:2006+A1:2009 | PD6662:2010 |
Certification type |
IMQ |
Certificate number |
CA12.01433 |
Electrical conformity |
CE |
Warranty |
2 years |